AC SERVICE EQUIPMENT
________________________________________________________
OWNERS MANUAL
SuperSKYE
MODEL EP6
R12/R134a A/C SERVICE CENTER
WARNING -- DO NOT MIX REFRIGERANTS
January 1, 2001
EP6manb
2
SKYE International Holdings, Inc. , 7441 Tower Street, Fort Worth TX. 76118
FOR TECHNICAL SUPPORT AND CUSTOMER SERVICE PLEASE CALL 1-800 722 SKYE (7593)
RECORD YOUR EQUIPMENT DETAILS BELOW: MODEL NO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Thank you for choosing SKYE. With proper set up and maintenance your equipment will provide years of trouble free service. [. . . ] Press again to restart the charge process from the interruption point. EXIT: Stops the charge process and returns the display to the main menu.
TOP OFF: Allows the addition of refrigerant to a charged system.
VEHICLE MUST BE RUNNING & AC SYSTEM ON MAX. The main screen shown in manual charge will display when the CONTINUE button is pushed. DISPLAY MODE: Press this button to select the type of measurement desired. Pressures will be displayed in PSI, Kpa or mBAR.
CHART: Allows the charge amount to be entered in the charge screen from the
refrigerant capacity chart. NOTES: Capacities shown in lbs/oz are automatically converted to Kg when using metric weight. Press the CAPACITY CHART button to access the capacity chart information.
Chevrolet Beretta, Corsica Camaro Caprice Cavalier Corvette
MAKE
1993
R12 44 50 36 36
R134a 32
SELECT
EXIT
2. Press the button below the window showing MAKE to toggle to YEAR then to MODEL. Make and model information displays alphabetically, year information is newest to oldest. Press the buttons to scroll through the information for the selection showing in the first button window. The line of the model information indicated by the is the line used for automatic entry of the charge amount. Press the SELECT button to enter the charge and display the main charging screen. Once in the main charging screen is displayed you may adjust the charge amount manually if desired using the and buttons then press the GO button to start the charge.
EXIT: Returns to the main menu.
Once the charge has been started the screen will display the amount being charged, the low and high side pressures and the HOLD button. NOTE: If the pressures displayed for the low and high sides are equal and the CHARGE COMPLETE message has not been displayed, start the vehicle and AC system to complete the charge. 15
16
Amount Charged _____lbs _____oz
LOW ____
GO
HIGH ____
HOLD EXIT
When the charge is complete the display will prompt you to run the AC system operational check.
Amount Charged _____lbs _____oz
Close tank liquid valve Charge Complete Check AC system operation
DONE
Press the DONE button to return to the main menu. When the operational check has been completed disconnect the service hoses from the vehicle and recover the refrigerant trapped in the hoses.
MANUAL NCG CHECK PROCEDURE
The MANUAL NCG CHECK is designed to allow you to check for and purge non-condensable gas (AIR) after the refrigerant has had time to settle and reach ambient temperature. When this procedure is selected the LCD screen will display the following information. Press the DONE button after opening the tank vapor valve.
NCG CHECK OPEN TANK VAPOR VALVE
DONE
The following screen will be displayed.
TANK PRESSURE TARGET PRESSURE SYS TEMP TIME
If NCG is NOT detected, the screen will display refrigerant OK after the check. If NCG is detected, the following screen will be displayed.
16 TANK PRESSURE TARGET PRESSURE
SYS TEMP
17
PURGE
EXIT
Press and hold the purge button to release pressure from the tank. When the button is released, the previous screen will be displayed to recheck for NCG. This process may have to be repeated several times to purge large quantities of NCG. If the allowable purge weight limit is reached, you will be notified to wait 20 minutes and check NCG again.
RECOVERED OIL DRAIN PROCEDURE
The recovered oil drain function can be used any time another function is not in operation and is a normal part of the recovery procedure. [. . . ] Once all updates have been loaded, disconnect from the base computer and turn your SuperSKYE machine off for at least 15 seconds. When your SuperSKYE is turned on, the new information will be in effect. If you encounter problems in the update process, call 1-800-722-7593 for assistance.
ADDITIONAL FEATURES
DUCT TEMPERATURE PROBE
The duct temperature probe provides outlet air temperature information for the technician. This feature can be useful in identifying plenum and other air flow problems. [. . . ]